26
TNC 122
9 Machine Integration
4/97
MP1050
Analog voltage for rapid traverse
Input range: 4.5 to 11.0 [V]
MP1050.0
Axis X
MP1050.1
Axis Y
MP1050.2
Axis Z
MP1051
Lower limit of analog voltage
Input range:
0 to 35 [transformer increment]
(1 transformer increment = 2.93 mV)
MP1051.0
Axis X
MP1052.1
Axis Y
MP1053.2
Axis Z
MP70
Bipolar or unipolar analog voltage
Input: 0 or 2
0 = bipolar
1 = unipolar, traversing the position outputs 0 volt
2 = unipolar, traversing the position inverts the voltage
MP80
Supply voltage for position controller during rapid traverse
Input range: 0 to 2
0 = Reserved
1 = Controller input supplied with external voltage (MP1850)
2 = Controller input supplied with analog voltage from the control
MP1060
Acceleration during position approach
Input range: 0.001 to 3.0 [m/s
2
]
MP1060.0
Axis X
MP1060.1
Axis Y
MP1060.2
Axis Z
Deceleration during position approach
Input range: 0.001 to 3.0 [m/s
2
]
MP1060.3
Axis X
MP1060.4
Axis Y
MP1060.5
Axis Z
MP1810
k
v
factor
Input range: 0.10 to 10.00 [
m/min
mm
]
MP1810.0
Axis 1
MP1810.1
Axis 2
MP1810.2
Axis 3