beautypg.com

HEIDENHAIN TNC 122 Technical Manual User Manual

Page 31

background image


30

TNC 122

9 Machine Integration

4/97

When the axes reach the positioning window, markers M2008 to M2010 are set.

MP1030

Positioning window
Entry range: 0.001 to 2.000 [mm]

MP1030.0

Axis X

MP1030.1

Axis Y

MP1030.2

Axis Z

Encoder monitoring

Monitoring of the encoder signals must be activated with MP31.
If the signal amplitude is faulty the following error messages can appear:

ENCODER DEFECT

If the signal amplitude is no longer being evaluated

AMPL TOO SMALL

If the signal amplitude is too small

OVERLOAD

If the signal amplitude is too large

MP31

Monitoring of the amplitude of the encoder signals
Input values: 0 to 7

Bit 0

Axis X

+0 = no monitoring
+1 = monitoring active

Bit 1

Axis Y

+0 = no monitoring
+2 = monitoring active

Bit 2

Axis Z

+0 = no monitoring
+4 = monitoring active