4/97

TNC 122

9 Machine Integration

23

MP1320

Traverse direction for crossing over the reference marks with EXT start
Input values: 0 to 7

Bit 0

Axis X

+0 = positive
+1 = negative

Bit 1

Axis Y

+0 = positive
+2 = negative

Bit 2

Axis Z

+0 = positive
+4 = negative

MP1330

Feed rate for crossing over the reference marks
Entry range: 80 to 30 000[mm/min]

MP1330.0 Axis

X

MP1330.1 Axis

Y

MP1330.2 Axis

Z

MP1340

Sequence when crossing over the reference marks
Input values: 0 = no reference mark evaluation

1 = 1st axis
2 = 2nd axis
3 = 3rd axis

MP1340.0 Axis

X

MP1340.1 Axis

Y

MP1340.2 Axis

Z

MP1350

Sequence for crossing over reference marks
Input values: 0 = encoder with distance-coded reference marks

1 = encoder with one reference mark

MP1350.0 Axis

X

MP1550.1 Axis

Y

MP1350.2 Axis

Z

Set

Reset

M2556

Reference end position for axis X

PLC

PLC

M2557

Reference end position for axis Y

PLC

PLC

M2558

Reference end position for axis Z

PLC

PLC