11 Machine Parameters

41

Machine
Parameter

Function and input

Input value

MP4110

Time for timers T0 to T15
Input values: 0 to 65 535 [24 ms]

MP4110.0

Waiting time controller enable X

MP4110.1

Waiting time unclamp X start

MP4110.2

Waiting time clamp X stop

MP4110.3

Waiting time controller enable Y

MP4110.4

Waiting time unclamp Y start

MP4110.5

Waiting time clamp Y stop

MP4110.6

Waiting time controller enable Z

MP4110.7

Waiting time unclamp Z start

MP4110.8

Waiting time clamp Z stop

MP4110.9

SE pulse formation / duration

MP4110.10

Waiting time O5 traverse
direction, delay erosion start M36

MP4110.11

Delay time for rapid traverse
output O4 (night erosion switch-
off)

MP4110.12
MP4110.13
MP4110.14
MP4110.15

MP4120.0
to
MP4120.7

Preset value for counters C0 to C7
Input values: 0 to 65 535

MP4210

Setting a number in the PLC word range
D768 to D804
Input values: –9 999.999 to +9 999.999 [mm]

MP4210.0

X switch-off point for rapid trav.

MP4210.1

Y switch-off point for rapid trav.

MP4210.2

Z switch-off point for rapid trav.

MP4210.3

Position control loop to XYZ potentiometer=0,
NC stop, lag<0.5

Only with MP 4310.4 and .5 =1

MP4210.4

Number of D/A converter steps per PLC cycle
with control by PLC

Input approx. 0.4

MP4210.5

Multiplication factor for the feed rate
potentiometer
Potentiometer value * MP4210.5= NC % block

Input approx. 0.1 to 1.2
External pot. 100%: factor 0.66
External pot. 150%: factor 1.0

MP4210.6

MP4210.7

Selection of code no. for software level for
position control loop via PLC

Input 1 to 8 (for software level of
TNC 121, see Chapter 10)

MP4210.8
MP4210.9