9 Machine Integration

4/97

Sequence for “Automatic reference mark traverse” (pressing the machine START key).
MP1350.x = 0

Press the external START key

Trig dog

"Reference end position"

closed?

Machine moves

in direction from

MP1320.x

Machine moves in inverted

traverse direction from

MP1320.x

Two successive reference marks traversed

Is the machine

outside the software

limit switch range?

Machine moves to

software limit switch

Machine stops

No

Yes

Yes

No

Yes

No

Trip dog

"Reference end position" is

closed before two successive

reference marks are

traversed