beautypg.com

HEIDENHAIN TNC 122 Technical Manual User Manual

Page 40

background image


4/97

TNC 122

11 Machine Parameters

39

Machine
Parameter

Function and input

Input value

MP910.0-2

Software limit switch max. value
Input range:
–9 999.99 to +9 999.99 [mm]

MP920.0-2

Software limit switch min. value
Input range:
–9 999.99 to +9 999.99 [mm]

MP1010.0-5

Rapid traverse for normal and amplified
tachometer signals
Input range: 80 to 30 000 [mm/min]
MP1010.0-2 normal rapid traverse for X, Y, Z
MP1010.3-5 increased rapid trav. for X, Y, Z

MP1030.0-2

Positioning window
Input values: 0.005 to 2.000 [mm]

MP1040

Polarity of nominal value voltage for positive
traversing direction
Input values: 0 to 7
Bit 0

Axis X

+0 = positive
+1 = negative

Bit 1

Axis Y

+0 = positive
+2 = negative

Bit 2

Axis Z

+0 = positive
+4 = negative

If MP70 = 1, then MP1040 must
equal 0.

MP1050.0-2

Analog voltage for rapid traverse
Input values: 4.5 to 11 [V]

10 V

MP1051.0-2

Lower limit of analog voltage
Input values: 0 to 35 [ factor 2.93 mV]

MP1060.0-5

Acceleration
Input values: 0.001 to 3.000 [m/s

2

]

1060.0 to 1060.2: accelerate
1060.3 to 1060.5: decelerate

MP1110

Standstill monitoring
Input values: 0.001 to 30.000 [mm]

MP1140

Motion monitoring
Input values: 0.03 to 10 [V]

MP1320

Traverse direction when crossing over the
reference marks
Input values: 0 to 7
Bit 0

Axis X:

+ 0 = positive
+ 1 = negative

Bit 1

Axis Y:

+ 0 = positive
+ 2 = negative

Bit 2

Axis Z:

+ 0 = positive
+ 4 = negative