HEIDENHAIN TNC 122 Technical Manual User Manual
Page 40

4/97
TNC 122
11 Machine Parameters
39
Machine
Parameter
Function and input
Input value
MP910.0-2
Software limit switch max. value
Input range:
–9 999.99 to +9 999.99 [mm]
MP920.0-2
Software limit switch min. value
Input range:
–9 999.99 to +9 999.99 [mm]
MP1010.0-5
Rapid traverse for normal and amplified
tachometer signals
Input range: 80 to 30 000 [mm/min]
MP1010.0-2 normal rapid traverse for X, Y, Z
MP1010.3-5 increased rapid trav. for X, Y, Z
MP1030.0-2
Positioning window
Input values: 0.005 to 2.000 [mm]
MP1040
Polarity of nominal value voltage for positive
traversing direction
Input values: 0 to 7
Bit 0
Axis X
+0 = positive
+1 = negative
Bit 1
Axis Y
+0 = positive
+2 = negative
Bit 2
Axis Z
+0 = positive
+4 = negative
If MP70 = 1, then MP1040 must
equal 0.
MP1050.0-2
Analog voltage for rapid traverse
Input values: 4.5 to 11 [V]
10 V
MP1051.0-2
Lower limit of analog voltage
Input values: 0 to 35 [ factor 2.93 mV]
MP1060.0-5
Acceleration
Input values: 0.001 to 3.000 [m/s
2
]
1060.0 to 1060.2: accelerate
1060.3 to 1060.5: decelerate
MP1110
Standstill monitoring
Input values: 0.001 to 30.000 [mm]
MP1140
Motion monitoring
Input values: 0.03 to 10 [V]
MP1320
Traverse direction when crossing over the
reference marks
Input values: 0 to 7
Bit 0
Axis X:
+ 0 = positive
+ 1 = negative
Bit 1
Axis Y:
+ 0 = positive
+ 2 = negative
Bit 2
Axis Z:
+ 0 = positive
+ 4 = negative