3. Installation
Making Power Connections
How to Connect Two NV8000 Power Supplies for Monitoring
1 Facing the rear of one of the two NV8000, connect one end of the monitor cable (WC0046) to
the ‘PS Frame 2 Monitor’ DB25 connection, as shown in Figure 3-5 on page 30.
2 Facing the rear of the remaining NV8000, make a loop-through connection using the other end
of the monitor cable (WC0046) to the ‘PS Frame 2 Monitor’ DB25 connection, as shown in
Figure 3-5 on page 30.
Creating a “Y” Monitor Cable
A “Y” monitor cable is required when connecting two routers to a single NV6257. A “Y” cable has
one connector at one end and then splits into two separate connectors on the other end, creating a
“Y.” To create a monitor “Y” cable you need:
• Three male DB25 connectors
• Two standard DB25 straight-through cables with 25 circuits
Wire the pins on the DB25 connectors as listed in the following table. To ensure that the correct
connector is inserted in the corresponding connection, it is recommended that each connector be
labeled.
DB25
Pin
NV6257
Connector
Router 1 Connector
Router 2 Connector
20
PS_TACH
PS_TACH
PS_TACH
21
PS_ALARM1
PS_ALARM1
PS_ALARM5
19
PS_ALARM2
PS_ALARM2
PS_ALARM6
18
PS_ALARM3
PS_ALARM3
PS_ALARM7
17
PS_ALARM4
PS_ALARM4
PS_ALARM8
16
PS_ALARM5
NC
NC
15
PS_ALARM6
NC
NC
23
PS_ALARM7
NC
NC
22
PS_ALARM8
NC
NC
8
TEMP1
TEMP1
TEMP5
6
TEMP2
TEMP2
TEMP6
5
TEMP3
TEMP3
TEMP7
4
TEMP4
TEMP4
TEMP8
3
TEMP5
NC
NC
2
TEMP6
NC
NC
10
TEMP7
NC
NC
9
TEMP8
NC
NC
11
GND
GND
GND
12
GND
GND
GND
13
GND
GND
GND
14
GND
GND
GND