beautypg.com

L35 network configuration – Grass Valley K2 Storage System Instruction Manual v.3.2 Nov.18 2008 User Manual

Page 519

background image

July 15, 2008

K2 Storage System Instruction Manual

519

L35 network configuration

L35 network configuration

For a non-redundant system (L35) configure you would a Level 20 K2 Storage
System, with the following specifications:

• GigE switch configuration is the same as Level 20.

• On each GS K2 Media Servers, configure for the control network (one IP address)

and the media (iSCSI) network (two IP addresses).

• On the GS K2 Media Server that is the media file system and database server, do

not configure for the streaming (FTP) network.

• If there is no optional NH1-10GE K2 Media Server, on the GS K2 Media Server

that is not the media file system and database server, configure for the streaming
(FTP) network (one IP address).

• If there is an optional NH1-10GE K2 Media Server, on the GS K2 Media Server

that is not the media file system and database server, do not configure for the
streaming (FTP) network.

• If there is an optional NH1-10GE K2 Media Server, configure the NH1-10GE

server for control network (one IP address) and the streaming (FTP) network (one
IP address).

For a redundant system (L35R), configure as you would a Level 20R K2 Storage
System, taking the above specifications into consideration.