WCU menu settings
Some WCU settings are changed in a menu which is accessed
via the Data board. When you enter the menu system, the Data
board display shows a two-letter abbreviation which must be
read from top to bottom. The code corresponds to a particular
menu, submenu or parameter. To change a WCU menu
setting proceed as follows:
1.
Remove the front panel marked DATA BOARD from the
WCU.
2.
Reach into the opening, push the Rotary/push button
at the front of the Data board and then rotate it.
3.
Scroll through the different settings until the display
shows the abbreviated name you want.
4.
Push the Rotary/push button to select the submenu,
scroll to the desired setting and push the Rotary/push
button again to select it.
5.
Push the Rotary/push button again to leave the menu.
The following menus are available:
CA - Camera number
Each camera in the system can be given a unique camera
number. This number must be set in the camera, the
WCU and a connected OCP if present.
To set the camera number in the WCU push the rotary/
push button and use the rotary button to select a
Setting up the WCU (cont.)
camera number from 1 to 99. Push again to select the
number.
IP - Ethernet address mode
The WCU is set to Auto (AU) mode by default. Normally
you need not change this setting. If you wish to set the
IP address to a particular value push the rotary switch
once so the indication (NN) is displayed. You must use
the NetConfig application to set the IP address (future
option).
RY - On-air red/yellow mode
Standard (ST) or Independent (ID).
OR - On-air red mode
Open/High (OH); High/Open (HO); Low/High (LH) or
High/Low (HL).
OY - On-air yellow mode
Open/High (OH); High/Open (HO); Low/High (LH) or
High/Low (HL).
CL - Call input mode
Open/High (OH); High/Open (HO); Low/High (LH) or
High/Low (HL).
OF - 7-segment display off
When selected, the menu display automatically switches
off after a few seconds.
a. Dry contact (no ground, no voltage)*
* a common return (not ground!) can be used for the three functions.
b. Common ground (connect one lead only to ground)*
* use either Send or Return only, do not mix.
c. Voltage level Send lead (0 to 2.5 Vdc, 4 to 24 Vdc)*
* isolated from ground.
d. Open / voltage level Send lead (open, 4 to 24 Vdc)*
* isolated from ground.
Signalling inputs
There are four connection methods for the Call, On-air and
Iso (On-air yellow) signalling functions:
a.
Dry contact
b.
Common ground
c.
Voltage level Send lead
d.
Open / voltage level Send lead
A selection in the menu allows you to make the state of the
function (on or off) correspond to a particular input
signal.There are two leads for each connection - Send and
Return.
The following tables show the selectable states for each of the
four connection methods.
Menu setting
Input shorted
Input open
LH
Function ON
Function OFF
HL
Function OFF
Function ON
Menu setting
Input grounded
Input open
LH
Function ON
Function OFF
HL
Function OFF
Function ON
Menu setting
Input 0 to 2.5V
Input 4 to 24V
LH
Function ON
Function OFF
HL
Function OFF
Function ON
Menu setting
Input open
Input 4 to 24V
OH
Function ON
Function OFF
HO
Function OFF
Function ON
Function
Send pin
Return pin
Call
2
10
Iso
3
11
On-air
4
12