Frame sync web page – Grass Valley 8985FS v.1.3.2 User Manual

Page 48

background image

48

8985FSP/FS — Instruction Manual

Configuration

Frame Sync Web Page

Use
this
link

The Frame Sync web page (

Figure 23 on page 50

for Local or Reference Bus

reference and

Figure 24 on page 51

for Input reference) provides horizontal

and vertical timing and loss of signal controls for the 8985FSP module.

Note

The controls available on the Frame Sync page depend on the Output Timing
Source selected on the System Config web page.

Timing Adjustment

When the Frame Sync option is present and the

Local

output timing source

is selected, horizontal and vertical timing adjustments can be made on the
output video as required relative to the external reference with the fol-
lowing controls

H Timing (Pixels)

– the horizontal timing can be adjusted in pixels relative

to the external reference.

V Timing (Lines)

– the vertical timing can be adjusted in lines relative to

the external reference.

Multi-Frame Delay

– this control allows you to add up to 6 frames of delay.

When the H and V Timing controls are set to maximum, the total delay
of the module will be 8 frames (when

Minimum Delay Mode

is not

selected).

Minimum Delay Mode

A Minimum Delay Mode can be enabled to bypass portions of the frame
sync memory to allow an absolute minimum amount of delay through the
module. It is a special mode allowing the user to select a throughput delay
of about 300 pixel periods when the input is synchronous and its position
with respect to the reference is well known. To enable this mode, check the

Enabled

checkbox.

Note

Delay can be added when in Minimum Delay Mode without causing video dis-
tortion up to one line short of a whole frame period of user delay. For normal
delay operations, Minimum Delay mode should be disabled.

Loss of Signal Operation

Set the operation to be performed by the module upon loss of input signal
when a Local external reference is present (

Auto Blue

,

Auto Freeze

, or

Pass

).

When there is no external reference (output timing set to Input), the
module will default to pass the signal to the output.

Manual Freeze Mode

Select one of the radio buttons (

Frame

or

Field

) to perform a manual freeze

on the output

.