8985FSP/FS — Instruction Manual

39

Configuration

I/O Config Web Page

Use
this
link

Use the I/O Config web page (

Figure 17 on page 40

) for the following:

Rear Connectors

All of the input and output connectors on the corresponding 8985FSP rear
module are illustrated on the I/O Config web page. The inputs can be con-
figured with the following controls:

Signal Naming

– type the desired input name (up to 11 characters) into the

corresponding boxes for each input. The status of each input is indi-
cated by the color of the display.

Reporting Enabling

– status reporting of each input type can be enabled or

disabled by selecting or deselecting the corresponding checkbox in the

Reporting Enabled

column for each input type. You may disable reporting

for inputs not being used if desired to avoid error messages. The

Reporting

Enabled

column is also used when an SNMP monitoring appli-

cation such as NetCentral is installed.

Refer to Status Monitoring Summary

on page 70

for a summary of the

color coding and using an SNMP monitoring application.

Note

Outputs are not monitored in this application.