8985FSP/FS — Instruction Manual
Power Up
Table 2. Board Front Edge LED Names and Meaning
LED
Indication
Condition
FAULT
(red)
Off
Normal operation.
On continuously
Module has detected an internal fault.
Flashing
Indicates a warning condition such as configuration problems or missing video. Check inputs and configuration settings.
COMM
(yellow)
Off
No activity on frame communication bus.
3 Quick Pulses
Locate Module command received by the module from a remote control system.
Short flash
Activity present on the frame communication bus.
CONF
(yellow)
Off
Module is in normal operating mode.
On continuously
Module is initializing, changing operating modes or programming hardware.
3 Quick Pulses
Locate Module command received by the module from a remote control system.
PWR
(green)
Off
No power to module or module’s DC/DC converter failed.
On continuously
Normal operation, module is powered.
REM OVR
(green)
Off
Not used on these modules, no local configuration controls.
On
FRM1
(green)
Off
Reference frame bus is disabled to frame on Genlock web page or no Genlock submodule is installed in slot 1.
On
Reference frame bus is enabled on Genlock web page and Genlock submodule is installed in slot 1.
FRM2
(green)
Off
Reference frame bus is disabled to frame on Genlock web page or no Genlock submodule is installed in slot 3.
On
Reference frame bus is enabled on Genlock web page and Genlock submodule is installed in slot 3.
VID IN
(green)
Off
Indicates no valid input signal is being detected.
On
Indicates a valid input signal is being detected.
REF IN
(green)
On
Indicates no valid reference signal is being detected or signal is not locked.
Off
Indicates a valid reference signal is present and locked.