Status is reported for each of the following video or reference signals:
•
Video In – indicates the status of the video input to the module from the
coax BNC, or one of two possible fiber optic inputs (depending on the
type of fiber optic connector installed).
•
Video Out – (gray) not monitored in this application.
•
Genlock Ref In – indicates the status of the external genlock reference
signal at BNCs J1 and J3 (Genlock Loop).
•
Local Ref – indicates the status of the internally generated genlock ref-
erence signal from the 8900GEN-SM submodule to the front module.
•
Frame Bus – indicates the status of the communication bus between the
8900NET module and the module.
•
Ref 1 and Ref 2 In (From Frame) – the Ref 1 arrow will be present when
Frame Bus 1 has been enabled on the module in slot 1. The Ref 2 arrow
will be present when Frame Bus 2 has been enabled on the module in
slot 3 of the frame.
Warning/Fault/Message Reporting
Faults, warnings, and informational messages from the module are dis-
played between the double bars below the graphic.
Note
Many of these warnings are informational only and concern frame rate com-
patiblilty. Pay close attention to the frame rate compatibility explanations and
tables in this manual.
Module Status
Module status for the front and rear modules (and any submodules if appli-
cable) are reported as PASS, WARNING, ERROR, or EMPTY on the right at
the bottom of the display.
Front Module Information
Information about the module, such as part number, serial number, hard-
ware revision and software, firmware, and boot versions, and asset tag
number (assigned on the Slot Config Web Page
) are given on the
left at the bottom of the display.