8921ADT Instruction Manual

Configuration

Slot Config Page

Use the Slot Config page (

Figure 19 on page 43

) to perform the following

functions on the 8921ADT module:

Locate Module

– selecting the On pulldown flashes the yellow COMM

and CONF LEDs on the front of the module so it can be located in the
frame.

Slot Identification

– You may identify the module by typing a specific

name in the

Name

field. The assigned name is stored on the 8900NET

module and travels with the 8900NET module if it is moved to another
frame. Select

Default

to enter the factory default module name.

Slot Memory

– the slot configuration for each media module is automati-

cally saved periodically (once an hour) to the 8900NET module in that
frame. You may also select the

Learn Module Config

button at any time to

save the current configuration for this slot. The configuration is saved
on the 8900NET module. If the 8900NET module is removed or
powered down, the stored configurations are not saved.

When the

Restore upon Install

box has been checked, the current configu-

ration saved to this slot is saved as slot memory. When the current
module is removed and another module of the same type is installed,
the configuration saved to the 8900NET module will be downloaded to
the new module. The box must be checked before the current module
with the saved configuration is removed.

Hardware Switch Controls

– a read-only status report of 8900NET module

switch settings for Module Status Reporting and Asynchronous Status
Reporting. These functions must be enabled for the following Slot
SNMP Trap Reports to function.

Slot SNMP Trap Reports

– displayed only when the SNMP Agent software

has been installed on the 8900NET module. Slot SNMP traps can be
enabled only when the hardware switches for Module Fault reporting
and Asynchronous Status reporting are in enabled on the 8900NET
module (dipswitch S1 segment 7 and dipswitch S2 segment 1).

The enabled SNMP traps will be reported to any SNMP manager that
is identified as an SNMP Report Destination in 8900NET configuration.
Trap severity is read-only hard-coded information that is interpreted
and responded to by the SNMP Manager software configuration.

SNMP reporting can be also be disabled for individual signal inputs on
the I/O Config and Video Composite In web pages.