8921adt module onboard configuration settings – Grass Valley 8921ADT User Manual
Page 26
26
8921ADT Instruction Manual
Configuration
•
CONTROL (paddle) switch – actuates or selects the desired setting for
the selected function when the switch is held momentarily in either the
up or down position.
•
CONF (configuring) yellow LED – when on, indicates the module is
programming hardware.
8921ADT Module Onboard Configuration Settings
To make a configuration setting:
1.
Rotate the CONTROL rotary switch to Bank 1 (BANK 2 LED off) or
Bank 2 BANK 2 LED on) and to the desired function within that bank.
2.
Move the paddle switch to the up or down position and hold
momentarily to set the desired function (refer to
).
Note
Holding the paddle switch in the up or down position for more than a half
second will automatically accelerate through the value range for parameters
with 256 or more values. The full range can be accessed in about 10 seconds.
Table 5. CONTROL Rotary and Paddle Switch Functions
Rotary
Switch
Setting
Paddle
Switch Up
Paddle
Switch Down
Function Description
Bank 1 (BANK 2 LED off)
Bank 1 (BANK 2 LED off)
0
–
–
Default position for normal operation (paddle has no effect).
1
Increase
Decrease
Adjust maximum input level for inputs 1 and 2 together.
1
2
Increase
Decrease
Adjust maximum input level for inputs 3 and 4 together.
1
3
Increase
Decrease
Adjust maximum input level for input 1 separately.
4
Increase
Decrease
Adjust maximum input level for input 2 separately.
5
Increase
Decrease
Adjust maximum input level for input 3 separately.
6
Increase
Decrease
Adjust maximum input level for input 4 separately.
7
Increment input #
Decrement input #
Select input channel to be used for Ch A (L) on AES 1 output.
8
Increment input #
Decrement input #
Select input channel to be used for Ch B (R) on AES 1 output.
9
Increment input #
Decrement input #
Select input channel to be used for Ch C (L) on AES 2 output.
A
Increment input #
Decrement input #
Select input channel to be used for Ch D (R) on AES 2 output.
B
Reference In
Free Run
Select the reference source input to lock or free run.
C
Enable
Disable
Auto tracking enable or disable.
D
-
–
Not used
E
Recall
Save
Save and recall current user settings.
F
Recall
–
Recall the following factory defaults:
Maximum input levels to + 24 dBu
Output gains to 0 dB
Delay to 0 sec
Input mapping to Inputs 1, 2 = AES 1 A, B, Inputs 3, 4 to AES 2 C, D