beautypg.com

8921adt module onboard configuration settings – Grass Valley 8921ADT User Manual

Page 26

background image

26

8921ADT Instruction Manual

Configuration

CONTROL (paddle) switch – actuates or selects the desired setting for
the selected function when the switch is held momentarily in either the
up or down position.

CONF (configuring) yellow LED – when on, indicates the module is
programming hardware.

8921ADT Module Onboard Configuration Settings

To make a configuration setting:

1.

Rotate the CONTROL rotary switch to Bank 1 (BANK 2 LED off) or
Bank 2 BANK 2 LED on) and to the desired function within that bank.

2.

Move the paddle switch to the up or down position and hold
momentarily to set the desired function (refer to

Table 5

).

Note

Holding the paddle switch in the up or down position for more than a half
second will automatically accelerate through the value range for parameters
with 256 or more values. The full range can be accessed in about 10 seconds.

Table 5. CONTROL Rotary and Paddle Switch Functions

Rotary

Switch

Setting

Paddle

Switch Up

Paddle

Switch Down

Function Description

Bank 1 (BANK 2 LED off)

Bank 1 (BANK 2 LED off)

0

Default position for normal operation (paddle has no effect).

1

Increase

Decrease

Adjust maximum input level for inputs 1 and 2 together.

1

2

Increase

Decrease

Adjust maximum input level for inputs 3 and 4 together.

1

3

Increase

Decrease

Adjust maximum input level for input 1 separately.

4

Increase

Decrease

Adjust maximum input level for input 2 separately.

5

Increase

Decrease

Adjust maximum input level for input 3 separately.

6

Increase

Decrease

Adjust maximum input level for input 4 separately.

7

Increment input #

Decrement input #

Select input channel to be used for Ch A (L) on AES 1 output.

8

Increment input #

Decrement input #

Select input channel to be used for Ch B (R) on AES 1 output.

9

Increment input #

Decrement input #

Select input channel to be used for Ch C (L) on AES 2 output.

A

Increment input #

Decrement input #

Select input channel to be used for Ch D (R) on AES 2 output.

B

Reference In

Free Run

Select the reference source input to lock or free run.

C

Enable

Disable

Auto tracking enable or disable.

D

-

Not used

E

Recall

Save

Save and recall current user settings.

F

Recall

Recall the following factory defaults:
Maximum input levels to + 24 dBu
Output gains to 0 dB
Delay to 0 sec
Input mapping to Inputs 1, 2 = AES 1 A, B, Inputs 3, 4 to AES 2 C, D