beautypg.com

Frame capacity, Module placement in the gecko 8900-a audio frame – Grass Valley 8921ADT User Manual

Page 10

background image

10

8921ADT Instruction Manual

Installation

Frame Capacity

The 8921ADT module can be installed in all Gecko 8900-A audio frames
but with varying maximum quantities determined by frame cooling
capacity.

Table 2

provides the power capacity, cooling capacity, and

maximum module count for each frame type.

Note

Module capacity figures assume no other modules are in the frame.
X = Not recommended without forced air cooling.

Module Placement in the Gecko 8900-A Audio Frame

There are ten cell locations in the audio frame to accommodate audio mod-
ules. These are the left ten locations. Refer to

Figure 2

.

The two cells on the right are allocated for the power supplies. For addi-
tional information concerning the Power Supply module, refer to the 8900
Power Supply manual.

The third cell from the right is allocated for the Frame Monitor or 8900NET
Network Interface module. These modules provide health monitoring and
control options.

Figure 2. Gecko 8900 Series Frame

Table 2. Video Frame Power Capacity

Capacity Calculated

8900TX Frame

8900TF Frame

8900TFN Frame

Power (W)

100

100

100

Recommended Module Cooling (W)

30

90

90

8921ADT Modules

10

10

10

Frame Monitor or

8900NET Network

Interface Module

8900 Audio Media Modules

Power

Supplies

(only)

8157_04r1