beautypg.com

Operation indicator leds – Grass Valley 8921ADT User Manual

Page 15

background image

8921ADT Instruction Manual

15

Power Up

Operation Indicator LEDs

Refer to

Figure 5

and

Table 3

for the name and meaning of each of the board

edge operating indicators on the module circuit board.

Table 3. Board Edge LED Names and Meaning

LED

Indication

Condition

FAULT

(red)

Off

Normal operation.

On continuously

Module has detected an internal fault. (Refer to

Functional Description

on page 48

.)

Long Flash

User configuration problems. Reference input missing or not locked. Processor failed to
load/configure or diagnostics failed on one or more devices.

COMM

(yellow)

Off

No activity on frame communication bus.

3 Quick Pulses

Locate Module command received by the module from a remote control system.

Short flash

Activity present on the frame communication bus.

CONFIG

(yellow)

Off

Module is in normal operating mode.

On continuously

Module is initializing, changing operating modes or programming hardware.

3 Quick Pulses

Locate Module command received by the module from a remote control system.

PWR

(green)

Off

No power to module or module’s DC/DC converter failed.

On continuously

Normal operation, module is powered.

REM OVR

(yellow)

Off

Parameter settings match those set on module switches and jumpers.

On

A setting on the module circuit board switches or jumpers is being overridden by remote control
system.

TRK ON

(green)

Off

No delay tracking. Tracking signal not received.

On

Auto delay is receiving a tracking delay input.

LOCKED

(green)

Off

No reference is present or reference is present but not locked.

On

Module is timed to the reference input.

BANK 2

(yellow)

Off

Bank 1 of Control rotary switch is active.

On

Bank 2 of Control rotary switch is active.

INPUT 1-4

(green)

Off

Indicated input is not selected for AES output channel selected with CONTROL rotary switch.

On

Indicated input is selected for AES output channel selected with CONTROL rotary switch.

> –40 dBFS/CLIP

CH 1-4

(green/red)

Off

Input level is less than –40dBFS and not clipping.

Green

Input level is greater than –40dBFS and not clipping.

Red

Input level is greater than –40dBFS and clipping.