8921ADT Instruction Manual

21

Configuration

Reference Source

The module can lock to an external reference or free run. The reference
source can be selected with local or remote controls. If a reference signal is
connected to the loop-through input, the reference source should be set to

Reference In

. If no external reference is used, or you don not wish to have the

module lock to its reference input, set the module to

Free Run

.

Recalling Factory Defaults

When the factory defaults are recalled with either the local controls or the
remote control from the web page, the module will revert to the following
values:

Maximum input levels to + 24 dBu

Output gains to 0 dB

Delay to 0 sec

Input mapping to Inputs 1, 2 = AES 1 A, B, Inputs 3, 4 to AES 2 C, D

The following controls will default to the current on-board jumper and
rotary switch settings on the module:

Sample Rate – jumper J12 is set for 48 kHz, the current default for this
release.

Output Resolution – will default to the jumper setting for 20 or 24 bit
word length on jumper J13 for AES 1 and jumper J14 for AES 2.

Output processing mode – will default to the rotary switch setting on
rotary switch SW1 for AES 1 and SW2 for AES 2.