Service
Service
The 2031RDA-SM/-MM modules make extensive use of surface-mount
technology and programmed parts to achieve compact size and adherence
to demanding technical specifications. Circuit modules should not be ser-
viced in the field unless otherwise directed by Customer Service.
Power-up Diagnostics Failure
If the module has not passed self-diagnostics, do not attempt to trouble-
shoot. Return the unit to Grass Valley (see
Troubleshooting
If your module is not operating correctly, proceed as follows:
•
Check frame and module power. If power is not present, check the fuse
and voltage testpoints on the module as illustrated in
.
•
Check for presence and quality of input signals.
•
Verify that source equipment is operating correctly.
•
Check cable connections.
Figure 16. Location of Module Fuse
8318_03
F1
2A
125V
J108
J108
Voltage
Test Points
Fuse: F1, 2A, 125V
+24V
+5V
GND
GND
+3.3V
TP 6
GND