2031RDA-SM/-MM Instruction Manual

23

Configuration and Monitoring

The following parameter controls are provided on the Settings web page.
Select the

Apply

button after each parameter selection.

Input

Select

Coax

or

Fiber

as the input to the module.

Mode

Set the reclocking mode to one of the following with the menu pulldown:

Bypass

– reclocking is completely bypassed. The input signal passes

directly to the outputs without reclocking.

Auto

– if the module detects the input signal as one of the SMPTE

standard definition rates (143 Mb/s, 177 Mb/s, 270 Mb/s,
360 Mb/s, or 540 Mb/s), it will reclock the signal at that rate. If one
of these rates is not detected, the module will not reclock the signal
(bypass the reclocker) and distribute the signal to the outputs.

Auto Reclock

– if the module detects the input signal as one of the

SMPTE standard definition rates (143 Mb/s, 177 Mb/s, 270 Mb/s,
360 Mb/s, or 540 Mb/s), it will reclock the signal at that rate. If one
of these rates is not detected, the signal will not be reclocked and
will be passed to the output as is (corrupted).

Note

This mode will not reclock/bypass DVB-ASI signals reliably. Use the Auto
mode for these signal types.

Manual 143Mb

– the module will attempt to reclock the input signal

at 143 Mb/s. If this signal rate is not detected, the signal will not be
reclocked and will be passed to the output as is (corrupted).

Manual 177Mb

– the module will attempt to reclock the input signal

at 177 Mb/s. If this signal rate is not detected, the signal will not be
reclocked and will be passed to the output as is (corrupted).

Manual 270Mb

– the module will attempt to reclock the input signal

at 270 Mb/s. If this signal rate is not detected, the signal will not be
reclocked and will be passed to the output as is (corrupted).

Manual 360Mb

– the module will attempt to reclock the input signal

at 360 Mb/s. If this signal rate is not detected, the signal will not be
reclocked and will be passed to the output as is (corrupted).

Manual 540Mb

– the module will attempt to reclock the input signal

at 540 Mb/s. If this signal rate is not detected, the signal will not be
reclocked and will be passed to the output as is (corrupted).

Optic TX

Use this control to enable or disable the optical output of the module.