Appendix b frus and compatibility matrixes, Mpus, Service modules – H3C Technologies H3C SecPath M9000 Series User Manual
Page 59: Lpus

51
Appendix B FRUs and compatibility matrixes
MPUs
MPU is the core of the control management plane for the M9000 gateway series. The MPU model
available for the M9000 gateway series is NSQ1SUPB0.
An M9000 gateway requires one MPU to operate correctly. You can install one MPU, or two MPUs for
redundancy
Table 16 MPU specifications
Item Description
Interfaces
•
One console port for local or remote dialup configuration management
•
One 10/100/1000BASE-T Ethernet interface for management and upgrade
Interface transmission
rate
•
Console port—No greater than 115200 bps and defaults to 9600 bps
•
10/100/1000BASE-T interface—10/100/1000 Mbps
Cables and max
transmission distance
•
Console port—15 m (49.21 ft) over common asynchronous serial interface cable
•
10/100/1000BASE-T interface—100 m (328.08 ft) over Category-5 twisted
pairs
For more information about the NSQ1SUPB0, see H3C SecPath M9000 NSQ1SUPB0 MPU Card
Manual.
Service modules
The services modules available for the M9000 security gateway are described in
Table 17 Service module specifications
Model Description Interface
Connector
NSQ1FWCEA0
Firewall service
module
1 console port
RJ-45
2 Gigabit combo interfaces. Each combo
interface includes:
•
One 10/100/1000BASE-T copper port
•
One 1000BASE-X SFP fiber port
RJ-45
LC
For more information about the service modules, see the card manuals that come with the service
modules.
LPUs
The LPUs available for the M9000 gateway series are described in
.