beautypg.com

Software upgrade in conventional methods, Preparations for software upgrade, Installing a secblade card in the switch – H3C Technologies H3C SecBlade SSL VPN Cards User Manual

Page 21: Setting hyperterminal parameters

background image

15

Software Upgrade in Conventional Methods

SecBlade cards provide the BootWare menu and a CLI, through either of which you can configure,

manage, and upgrade the cards.

NOTE:

The upgrade procedures of FW, AFD, AFC, ACG, IPS, SSL VPN, LB, NS and ADE cards are similar unless
otherwise specified in this chapter. This chapter illustrates the procedures for upgrading the software of an

LSB1FW2A0 on the S9500.

Preparations for Software Upgrade

Before upgrading the software in conventional methods, set up a configuration environment.

Installing a SecBlade card in the switch

Install a SecBlade card (LSB1FW2A0) in the S9500 in the way you install an LPU. For more information

about the installation, see H3C S9500 Series Routing Switches Installation Manual.

Connecting the console interface to a configuration terminal (usually a PC)

Plug the DB-9 connector of the console cable into the serial interface on the PC and the RJ-45 connector

into the console interface on the SecBlade card.
For the SecBlade card of the S5800 series switch, you need to connect the RJ-45 connector of the console

cable to the console port of the switch, and then execute the mcms connect slot 1 system subslot 3
command to redirect from the switch side to the SecBlade card.

Setting HyperTerminal parameters

The following describes how to set HyperTerminal parameters on the PC running Windows XP:

1.

Select Start > Programs/All Programs > Accessories > Communications > HyperTerminal to
establish a HyperTerminal connection.

2.

In the Connection Description dialog box, enter a name for the connection and click OK, as shown
in

Figure 6

.