Configuring ethernet interface parameters – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 84

background image

76

Step2

To improve the upgrading speed, first modify the serial interface baud rate. For more information, see

Modifying serial communication parameters

Step3

Select 2 in the serial interface submenu. The following prompt appears:

Please Start To Transfer File, Press To Exit.

Waiting ...CCCCCCCCCC

Step4

Select and send the application file in HyperTerminal. The procedure for upgrading an application file

is the same as upgrading the BootWare. For more information, see “

Upgrading the BootWare through

a serial connection

.”

NOTE:

The size of an application program is typically over 10 MB. Even at the baud rate of 115,200 bps, the
upgrade takes about 30 minutes. Therefore, you are recommended to upgrade an application program

through an Ethernet interface.

Upgrading applications through an Ethernet

interface

Select 3 in the BootWare main menu to enter the Ethernet interface submenu. For more information about
this submenu, see “

Ethernet interface submenu

.”

Configuring Ethernet interface parameters

Before upgrading an application program through an Ethernet interface, configure the Ethernet interface

of the access controller, as follows.
Select 3 in the BootWare main menu to enter the Ethernet interface submenu. Then, select 5 to enter the

Ethernet interface configuration submenu:

========================================================

|Note: '.' = Clear field. |

| '-' = Go to previous field. |

| Ctrl+D = Quit. |

================================================================================

Protocol (FTP or TFTP) :tftp

Load File Name :wx6103.bin

Target File Name :wx6103.bin

Server IP Address :192.168.0.179

Local IP Address :192.168.0.1

Gateway IP Address :192.168.0.10

NOTE:

When configuring a parameter, you can enter a new value directly, or press Enter to accept the default
value that follows a colon. Type . to clear the current input, - to return to the previous parameter field, and

Ctrl+D to quit from the parameter configuration interface.

The WX6103 access controller supports only the 10/100/1000Base-TX out-of-band management
Ethernet interface for application upgrade.