Slot arrangement

As a self-developed 3U device, each MSR 30-60 router provides four SIC slots and six MIM slots

respectively, delivering expansion of access and service capabilities. In addition, the SIC slide rail
between Slot 1 and Slot 2 can be removed so that two SIC slots can be extended to form a DSIC slot.

Similarly, Slot 3 and Slot 4 can be extended to form another DSIC slot, Slot 7 and Slot 8 can be arranged

to serve as a DMIM slot, and Slot 9 and Slot 10 together serve as another DMIM slot.

Figure 18 Slots on an MSR 30-60 router

Panel LEDs

Table 14 Front panel LEDs of an MSR 30-60 router

LED Description

PWR

Power LED:

ON means the system provides power for cards normally.

OFF means the system does not supply power for cards.

SYS

Hardware system operation LED:

Blinking means the system is operating normally.

Steady ON or steady OFF means the system does not operate normally.

USB0

OFF means the USB interface has not been connected to a host.

Steady green means the USB interface has been connected to a host and the host can be
removed.

Blinking green means data is being transferred to/from the host and the host cannot be
removed now.

CF

CF card LED:

Steady green means the CF card is in the slot and can be identified by the router.

Blinking green means the CF card is being accessed and cannot be removed.

Steady yellow means the CF card is in the slot but cannot be identified by the router.

OFF means no CF card is inserted or the CF card cannot be identified.

Table 15 Rear panel LEDs of an MSR 30-60 router

LED Description

GE LED

OFF means no link is present.

Steady green means a 1000 Mbps connection has been established.

Blinking green means data is being received or transmitted at a speed of 1000 Mbps.

Steady yellow means a 10/100 Mbps connection has been established.