Rack-mounting procedures at a glance – H3C Technologies H3C S5820V2 Series Switches User Manual

Page 14

background image

6

Figure 3 Rack-mounting rail kit

(1) Chassis rail

(2) Slide rail

Rack-mounting procedures at a glance

Figure 4 Rack-mounting procedure

NOTE:

If a rack shelf is available, you can put the switch on the rack shelf, slide the switch to an appropriate
location, and attach the switch to the rack with the mounting brackets.

To rack-mount the switch, you must use both the mounting bracket and the rack-mounting rail kit.

Attaching the mounting brackets, chassis rails, and grounding
cable to the chassis

The switch has one front mounting position (near the network ports) and one rear mounting position (near

the power modules).
The S5830V2-24S has one primary grounding point (with a grounding sign) and one auxiliary

grounding point. The S5820V2-48S, S5820V2-52QF, S5820V2-52QF-U, S5820V2-52Q, and
S5820V2-54QS-GE switches each have one primary grounding point (with a grounding sign) and two

auxiliary grounding points. Use the primary grounding point whenever possible. If the primary

grounding point fails or is not suitable for the installation site, use one of the auxiliary grounding points.

1

2