Step Command

Remarks

2.

Specify the mode for
establishing a BFD session.

bfd session init-mode { active |
passive }

By default, active is specified.

3.

Enter interface view.

interface interface-type
interface-number

N/A

4.

Configure the authentication
mode for single-hop control

packets.

bfd authentication-mode simple
key-id { cipher cipher-string | plain

plain-string }

By default, single-hop BFD packets
are not authenticated.

5.

Enable the Demand BFD
session mode.

bfd demand enable

By default, the BFD session is in
Asynchronous mode.

6.

Enable the echo packet mode. bfd echo enable

By default, the echo packet mode
is disabled.
If you enable the echo packet
mode for a BFD session in which

control packets are sent and the

session goes up, BFD periodically
sends echo packets to detect link

connectivity and decrease control

packet receive rate.

7.

Configure the minimum
interval for transmitting

single-hop BFD control
packets.

bfd min-transmit-interval value

By default, the minimum interval for
transmitting single-hop BFD control
packets is 400 milliseconds.

8.

Configure the minimum

interval for receiving

single-hop BFD control
packets.

bfd min-receive-interval value

By default, the minimum interval for

receiving single-hop BFD control
packets is 400 milliseconds.

9.

Configure the single-hop

detection time multiplier.

bfd detect-multiplier value

The default setting is 5.

To configure control packet mode for multi-hop detection:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Specify the mode for
establishing a BFD session.

bfd session init-mode { active |
passive }

By default, active is specified.

3.

Configure the authentication
mode for multi-hop BFD

control packets.

bfd multi-hop authentication-mode

simple key-id { cipher cipher-string
| plain plain-string }

By default, no authentication is
performed.

4.

Configure the destination port

number for multi-hop BFD
control packets.

bfd multi-hop destination-port
port-number

The default setting is 4784.

5.

Configure the multi-hop
detection time multiplier.

bfd multi-hop detect-multiplier
value

The default setting is 5.

6.

Configure the minimum
interval for receiving multi-hop

BFD control packets.

bfd multi-hop min-receive-interval
value

By default, the minimum interval for
receiving multi-hop BFD control

packets is 400 milliseconds.