beautypg.com

H3C Technologies H3C S6800 Series Switches User Manual

Page 43

background image

35

Admin Status : Up State : Backup

Config Pri : 100 Running Pri : 100

Preempt Mode : Yes Delay Time : 5

Become Master : 401ms left

Auth Type : None

Virtual IP : 10.1.1.111

Master IP : 10.1.1.1

The output shows that Switch A is operating as the master in VRRP group 1 to forward packets from

Host A to Host B.
# Disconnect the link between Host A and Switch A, and verify that Host A can still ping Host B.
(Details not shown.)
# Display detailed information about VRRP group 1 on Switch B.

[SwitchB-Vlan-interface2] display vrrp verbose

IPv4 Virtual Router Information:

Running Mode : Standard

Total number of virtual routers : 1

Interface Vlan-interface2

VRID : 1 Adver Timer : 100

Admin Status : Up State : Master

Config Pri : 100 Running Pri : 100

Preempt Mode : Yes Delay Time : 5

Auth Type : None

Virtual IP : 10.1.1.111

Virtual MAC : 0000-5e00-0101

Master IP : 10.1.1.2

The output shows that when Switch A fails, Switch B takes over to forward packets from Host A to
Host B.
# Recover the link between Host A and Switch A, and display detailed information about VRRP
group 1 on Switch A.

[SwitchA-Vlan-interface2] display vrrp verbose

IPv4 Virtual Router Information:

Running Mode : Standard

Total number of virtual routers : 1

Interface Vlan-interface2

VRID : 1 Adver Timer : 100

Admin Status : Up State : Master

Config Pri : 110 Running Pri : 110

Preempt Mode : Yes Delay Time : 5

Auth Type : None

Virtual IP : 10.1.1.111

Virtual MAC : 0000-5e00-0101

Master IP : 10.1.1.1

The output shows that after Switch A resumes normal operation, it becomes the master to forward

packets from Host A to Host B.

This manual is related to the following products: