Manually shutting down unidirectional links, Network requirements, Configuration procedure – H3C Technologies H3C S6800 Series Switches User Manual
Page 19
11
status is DOWN.
%Jul 11 17:42:58:603 2012 DeviceA IFNET/3/PHY_UPDOWN: FortyGigE1/0/2 link status is
DOWN.
%Jul 11 17:43:02:342 2012 DeviceA IFNET/3/PHY_UPDOWN: FortyGigE1/0/1 link status is
UP.
%Jul 11 17:43:02:343 2012 DeviceA DLDP/6/DLDP_NEIGHBOR_CONFIRMED: A neighbor was
confirmed on interface FortyGigE1/0/1. The neighbor's system MAC is 0023-8956-3600,
and the port index is 1.
%Jul 11 17:43:02:344 2012 DeviceA DLDP/6/DLDP_LINK_BIDIRECTIONAL: DLDP detected a
bidirectional link on interface FortyGigE1/0/1.
%Jul 11 17:43:02:353 2012 DeviceA IFNET/5/LINK_UPDOWN: Line protocol on the interface
FortyGigE1/0/1 is UP.
%Jul 11 17:43:02:357 2012 DeviceA IFNET/3/PHY_UPDOWN: FortyGigE1/0/2 link status is
UP.
%Jul 11 17:43:02:362 2012 DeviceA DLDP/6/DLDP_NEIGHBOR_CONFIRMED: A neighbor was
confirmed on interface FortyGigE1/0/2. The neighbor's system MAC is 0023-8956-3600,
and the port index is 2.
%Jul 11 17:43:02:362 2012 DeviceA DLDP/6/DLDP_LINK_BIDIRECTIONAL: DLDP detected a
bidirectional link on interface FortyGigE1/0/2.
%Jul 11 17:43:02:368 2012 DeviceA IFNET/5/LINK_UPDOWN: Line protocol on the interface
FortyGigE1/0/2 is UP.
The output shows that the port status and link status of both FortyGigE 1/0/1 and FortyGigE
1/0/2 are now up and their DLDP neighbors are determined.
Manually shutting down unidirectional links
Network requirements
As shown in
, Device A and Device B are connected with two fiber pairs.
Configure DLDP to detect unidirectional links. When a unidirectional link is detected, the administrator
must manually shut down the port.
Figure 6 Network diagram
Configuration procedure
1.
Configure Device A:
# Enable DLDP globally.
[DeviceA] dldp enable
# Configure FortyGigE 1/0/1 to operate in full duplex mode and at 40000 Mbps, and enable
DLDP on the port.