Hardware manual – ACTi I93 User Manual
Page 39

Hardware Manual
Consequently, to connect a second DI or DO device, use the GND (Black) and DI1 (Green)
cables to connect the second DI device, and the 12V (Red) and DO2 (Blue) cables for the second
DO device.
12V DC Speaker
(DO1 Device)
Outdoor PTZ
Alarm Button
(DI1 Device)
12V DC LED
(DO2 Device)
Infrared Sensor
(DI2 Device)
High Voltage DO Device Connection
Even though the camera provides 12V power, this may not be enough for some high voltage DO
devices, such as a ceiling light or a motor that opens or closes a gate. In this case, there is a
need to connect an external relay. See wiring scheme below:
Note that when choosing an appropriate relay, please refer to its specifications and make sure
they match the above design. The triggering circuit voltage has to be around 12V DC and the
switch-controlled circuit voltage has to match the external power supply (e.g. 110V AC or 220V
AC).
- I94 I95 I96 I910 KCM-8211 I96 2 MP Extreme WDR Day & Night HPoE Outdoor Speed Dome PTZ IP Camera with 30x Lens I915 2MP Outdoor PTZ Network Dome Camera with Night Vision & Heater B928 5MP Outdoor PTZ Network Speed Dome Camera with Night Vision B915 3MP Outdoor PTZ Network Speed Dome Camera with Night Vision