Consequently, to connect a second DI or DO device, use the GND (Black) and DI1 (Green)

cables to connect the second DI device, and the 12V (Red) and DO2 (Blue) cables for the second

DO device.

12V DC Speaker

(DO1 Device)

Outdoor PTZ

Alarm Button
(DI1 Device)

12V DC LED

(DO2 Device)

Infrared Sensor

(DI2 Device)

High Voltage DO Device Connection

Even though the camera provides 12V power, this may not be enough for some high voltage DO

devices, such as a ceiling light or a motor that opens or closes a gate. In this case, there is a

need to connect an external relay. See wiring scheme below:

Note that when choosing an appropriate relay, please refer to its specifications and make sure

they match the above design. The triggering circuit voltage has to be around 12V DC and the

switch-controlled circuit voltage has to match the external power supply (e.g. 110V AC or 220V

AC).