4-30
1. Ethernet
Read Double-words from PLC Memory
int HKEtn_ReadPlcMemory2(DWORD *dp,unsigned short Wordcnt,int
DeviceType,DWORD addr,char *lpAddr, int DFlag=1)
This function is retained until PLC data is transferred from the V7 series.
• Parameters
*dp
Target pointer of the data to be read
Wordcnt
Word count to be read (max. 1000 words)
DeviceType
Address of the device to be read (Refer to “Chapter 5 Connection to
PLCs.”)
addr
Top memory address to be read
For YOKOGAWA or YASKAWA PLCs, specify a number “
−1” for the
address (addr).
Example: D400
→ 399 D25 → 24
*lpAddr
IP address shown as a string of characters separated by dots
Example: “192.168.XXX.XXX”
DFlag
0, 1, 2 (Refer to page 4-29.)
• Return values
Success
TRUE
Failure
FALSE
Error details
Get using HKEtn_GetLastError ().
Contents
Word Count
No. 1
2
No. 2
2
•
•
•
•
•
•
No. n
2