Port, Format – Wavetronix SmartSensor HD (101-0415) - User Guide User Manual
Page 76
CHAPTER 7 • DATA
75
Figure 7.10 – Data Push
To enable data push, select the Event, Interval or Presence tab, then select which method
of communication and format you are using and turn the function on by checking the En-
abled checkbox.
Port
This allows you to select the SmartSensor HD communications port through which the
data will be pushed. If the sensor is pushing data on a half-duplex communication port, the
sensor may not respond to commands due to collisions on the communications bus.
Note
SmartSensor HD's native RS-232 and RS-485 ports are both half duplex.
Format
The following formats are available for all three data types:
˽
HD Format – This outputs the data in the native SS125 format (see the SmartSensor HD
Released Communications Protocols document for information on this format).
˽
SS105 Simple Format – This outputs the data in the SSHD SS105 emulation format
without a multi-drop header (see the SmartSensor HD Released Communications Pro-
tocols document for information on this format).
˽
SS105 Multidrop Format – This outputs the data in the SSHD SS105 emulation format
with a multi-drop header (see the SmartSensor HD Released Communications Protocols
document for information on this format).
For Event Data, there are five additional format options. All of them output the data in Z4
format. Z4 is a Wavetronix-specific protocol that allows sensors to talk to other Wavetronix