Visara CNA-8000 Installation User Manual
Page 51
![background image](https://www.manualsdir.com/files/808689/content/doc051.png)
CNA-8000 Installation and Configuration
707158-003
3-9
Connecting a TN3270E Client to a Specific LU
There are several ways to connect a TN3270E client to a specific LU on a specific Host
Circuit. These methods can be used
Using Client IP Address
Use Listening Port
Using Predefined Format
Using a Nickname
Here is a summary of what needs to be done for each of the methods.
Using Client IP Address:
Panel Action
Ports
One port configured for many clients
Pools Not
Required
Clients
Specify the port configured on the ports panel.
Specify the client’s IP address in the address field.
Specify the Host Circuit assignment in the Resource field.
Specify the LU assignment in the LU field.
Nicknames Not
Required
User IDs
Not Required
Using Listening Port:
Panel Action
Ports
One port configured for each client session
Pools Not
Required
Clients
Specify the port configured on the ports panel.
Specify the Host Circuit assignment in the Resource field.
Specify the LU assignment in the LU field.
Nicknames Not
Required
User IDs
Not Required but Recommended