Chapter 1. Installation
1-10
707158-003
Cabling for Token Ring
The Token Ring interfaces for the CNA-8000 each support both, RJ45 and 9-pin D
sockets. Each interface card supports a single interface so only one cable should be
plugged in at a time. RJ45 connectors should be inserted until you feel it click into place.
9-pin D connectors should be secured with captive screws. The Token Ring interface of
the CNA-8000 defaults to auto-detect the speed and can be plugged into a switch or a hub
running at 4 Mhz, 16 Mhz, or 100 Mhz. Note that the interface can be reconfigured to run
at a specific speed if desired. It should be noted that when connecting the CNA-8000 to a
Token Ring switch, it may be necessary to set the Token Ring to a specific speed in order
for the CNA-8000 Token Ring interface card to insert into the ring. If the interface does
not appear to be inserting automatically, try reconfiguring for the specific speed and try
again.
Recommended Minimum Cabling Type
Token Ring Speed
Minimum Twisted Pair Cable Type
4 Mbps
Cat 2
16 Mbps
Cat 3
100 Mbps
Cat 5
DB9 Interface
RJ45 Interface