Manufacturing info, Display alarm buffers -18, Manufacturing info -18 – Verilink DCSU 2911 (880-502647-001) Product Manual User Manual
Page 64

DCSU 2911 E1 Craft Interface
4-18
Verilink DCSU 2911 User Manual
Display Alarm
Buffers
To display the alarm buffer, enter O in the Net Port Alarm Menu.
The Alarm Buffer shows all major and minor alarms that have
occurred at each port. When an alarm is cleared, the time stamp
changes to reflect the time the alarm was cleared.
Figure 4-14 Alarm Buffer
When finished reviewing the alarm information, enter X to return to
the Main Menu. For example, in the sample display above, a major
alarm was reported on the DCSU 2911 in Shelf 1, Slot 1 at 6:38 pm.
It was caused by errors exceeding the AIS Threshold at port 1 of
this application module.
Manufacturing
Info
To display information on your firmware versions and CIM types,
choose I from the Main Menu.
Figure 4-15 Manufacturing Information
Sn
Severely Errored Second (SES) 15 min. Threshold/SES 24 hr. Threshold:
Select a threshold level.
15 minute
Threshold:
1—900
0 to disable
24 hour
Threshold:
1—86400
0 to disable
In
Bit Error Rate (BER) Threshold: Select a threshold level. Selecting
10
-9
will report more errors than 10
-4
.
Threshold:
1) DISABLE
2) 10E-4
3) 10E-5
4) 10E-6
5) 10E-7
6) 10E-8
7) 10E-9
X
Exit the Net Port Alarm Threshold Configuration Menu
Command
Description
Options
[1,1] DCSU 2911 > o
DCSU 2911 [1,1] AIS Cleared port 1 11-09-96 18:36:50
DCSU 2911 [1,1] AIS Major Alarm port 1 11-09-96 18:36:33
Press enter to continue
MANUFACTURING INFORMATION
Main Card CIM
Revision RM) 1 RC)
Date DM) 10/14/96 DC) 11/10/96
Serial number SM) 00594698 SC) 00486749
Manuf. Part No. MM) 310101776002 MC) 3111017323
Cage Code CM) OJE20 CC) OJE20
Type TM) DUAL CSU TC) CIM29001
Press enter to continue