Verilink DCSU 2911 (880-502647-001) Product Manual User Manual
Page 20

DCSU 2911 Quick Set-Up
2-6
Verilink DCSU 2911 User Manual
10. Type “T1”, then E
NTER
, to display the Configuration Menu
(Timing Options):
Figure 2-5 Configuration Menu (Timing Options)
a. Type “PC” to select the primary clocking source for the
DCSU. Enter the card number “2”.
b. Type “PS” to select the primary synchronization for the
DCSU. From the selection, select “1” to choose the Net 1
Port as the primary timing source.
c. Type “PA” to select the auto restore for the primary timing
source. At the prompt, type “Y” for yes to enable the auto
restore.
d. Type “SC” to select the secondary clocking source for the
DCSU. Enter the card number “2”.
e. Type “SS” to select the secondary synchronization for the
DCSU. From the selection, select “2” to choose the Net 2
Port as the secondary timing source.
f. Type “SA” to select the auto restore for the secondary
timing source. At the prompt, type “Y” for yes to enable the
auto restore.
g. Type “TC” to select the tertiary clocking source for the
DCSU. Enter the card number “2”.
h. Type “TS” to select the tertiary synchronization for the
DCSU. From the selection, select “5” to choose the Net 3
Port (Equipment Port 1) as the tertiary timing source.
i. Type “TA” to select the auto restore for the tertiary timing
source. At the prompt, type “Y” for yes to enable the auto
restore.
j. Exit the Configuration Menu (Timing Options) by typing
“X”.
11. Copy or “clone” the port configuration to the next port. Type
“C”, then E
NTER
, to display the prompt:
Enter the port to copy (1-4):
Enter the port to copy (1-4):
Enter the port to copy (1-4):
Enter the port to copy (1-4):
Type “1” to select the now configured Net Port 1. The prompt
will display:
A [127.255.255.0] [1,2] DCSU 2911 > t
-- DCSU 2911 CONFIGURATION MENU (TIMING OPTIONS)--
Current shelf timing source: Card 1, INTERNAL (PRIMARY)
Source Slot Number Synchronization Auto Restore
PRIMARY PC) 1 PS) INTERNAL PA) YES
SECONDARY SC) 1 SS) INTERNAL SA) YES
TERTIARY TC) 1 TS) INTERNAL TA) YES
R) Receive clock from shelf: YES
X) exit this screen
A [127.255.255.0] [1,2] DCSU 2911 >