Dcsu 2911 quick set-up, Installation, Dcsu 2911 quick set-up -1 – Verilink DCSU 2911 (880-502647-001) Product Manual User Manual
Page 15: Installation -1, Chapter

Verilink DCSU 2911 User Manual
2-1
Chapter
2
DCSU 2911 Quick Set-Up
This chapter provides step-by-step procedures for setting up your
DCSU 2911 module. This quick configuration guide makes the
following assumptions:
•
You are adding the DCSU 2911 and an NCM 2000 module to an
existing installation in a dual-line shelf.
•
You are putting two T1s on the two equipment (DSX-1) ports of
the DCSU 2911.
•
ESF/B8ZS T1s
•
You are using the NCM 2000 controller module in slot 1 of
shelf 1.
Figure 2-1
Example Configuration
NOTE: These procedures may not match your configuration. Use this
chapter as a guide for equipment installation. Chapter 3 provides
details on configuration options.
Installation
Do the following before installing the DCSU 2911:
•
Install all associated Access System 2000 shelves and power
supplies, as outlined in the
AS2000: The Basics
manual.
•
Install and test the NCM in slot 1.
Install the DCSU in slot 2 as outlined in the
AS2000: The Basics
manual.
Management
Terminal/PC
Full T1
24 DS0s
NCM 2000
DCSU 2911
DS1 Port
PBX, Router or
DSX-1 Port
Channel Bank
Full T1
24 DS0s
DS1 Port
PBX, Router or
DSX-1 Port
Channel Bank