Net port alarm threshold configuration submenu, Net port alarm threshold configuration submenu -15 – Verilink DCSU 2911 (880-502647-001) Product Manual User Manual
Page 61

DCSU 2911 E1 Craft Interface
Verilink DCSU 2911 User Manual
4-15
Figure 4-12 DCSU 2911 Net Port Alarm Menu
Following is a brief description of the alarm parameters:
Table 4-8
Net Port Alarm Menu Parameters
Net Port Alarm
Threshold
Configuration
Submenu
Display this menu by typing the command Tn from the Net Port
Alarm Menu (Figure 4-12).
-- DCSU 2911 NET PORT ALARM MENU --
N) NMS Address: 128.0.0.0
A) Card Alarm Reporting: NO
C) Configure Thresholds S) Alarm status
M) Enable alarm monitor O) Display Alarm Buffer
Tn) Set Default Thresholds X) exit this screen
[1,1] DCSU 2911 >
Command
Description
Options
N
NMS (Network Management System) Address: Use this option to set
Verilink’s ACP address (which is the address of the PC that will
receive the alarms). Though this address is significant for Node
Manager, it is not important for the Craft interface.
Address for alarm
destination such
as: 128.0.0.0
A
Card Alarm Reporting: Use this option to enable or disable cards
from sending alarms.
Yes or No
(Y/N)
C
Configure Thresholds: To disable any or all alarm conditions, enter a
threshold value of 0. To enable a condition, specify any non-zero
threshold value.
Refer to Table 3-9
for details on the
configuration
parameters.
S
Alarm Status: Displays the counts and intervals of the LOF, LOS, RAI,
AIS, BPV, ES, and SES registers.
Options:
R) Reset Counters: Restarts the values of the LOF, LOS, RAI, AIS, BPV,
ES 15-minute, ES 24-hours, SES 15-minute, and SES 24-hour counters.
It resets their values to 0.
X) Exit the Net Port Alarm Threshold Status Menu
M
Disable/Enable Alarm Monitor: Use this option to either activate or
deactivate monitoring shelf alarms.
Toggles between
Enable and
Disable
O
Display Alarm Buffer: Displays major and minor alarms.
Minor: These alarms do not affect traffic along the network line.
Major: These alarms indicate a condition where performance is
seriously affected, for example, a network line failure. It prevents
data from being reliably transmitted across the circuit.
This option also indicates any alarms that have been cleared.
Tn
Set Default Thresholds: Use this option to load the factory default
threshold settings.
Yes or No
(Y/N)
X