beautypg.com

Verilink DCSU 2911 (880-502647-001) Product Manual User Manual

Page 63

background image

DCSU 2911 E1 Craft Interface

Verilink DCSU 2911 User Manual

4-17

Net Port Alarm Threshold Configuration Menu Parameters

Command

Description

Options

Pn

Alarm Reporting: When alarm reporting is enabled, it will convey any

messages indicating alarms for each port. These alarms are declared to both

the ASCII interface as well as the Node Manager (if in use). If this option is

set to No, even if alarm reports for individual ports are requested, they will

not be reported. The LEDs will still turn yellow or red in an alarm condition.

This option is best set to No while setting up or reconfiguring your node,

and then set to Yes during normal operation.

Yes or No

(Y/N)

Fn

Loss-of-Frame (LOF) Threshold/LOF Interval: Use this option to indicate an

interval that is larger than the threshold.

Threshold:

1—86400

0 to disable

Interval:

3—86400

seconds

Ln

Loss of Signal (LOS) Threshold/LOS Interval: Use this option to indicate an

interval that is larger than the threshold.

Threshold:

1—86400

0 to disable

Interval:

3—86400

seconds

Rn

Remote Alarm Indication (RAI) Threshold/RAI Interval: Use this option to

indicate an interval that is larger than the threshold.

Threshold:

1—86400

0 to disable

Interval:

1—86400

seconds

An

Alarm Indication Signal (AIS) Threshold/AIS Interval: Use this option to

indicate an interval that is larger than the threshold.

Threshold:

1—86400

0 to disable

Interval:

1—86400

seconds

Bn

Bipolar Violation (BPV) Threshold/BPV Interval: Use this option to indicate an

interval that is larger than the threshold.

Threshold:

1—86400

0 to disable

Interval:

1—86400

seconds

En

Errored Seconds (ES) 15 min. Threshold/ES 24 hr. Threshold: An ES alarm

indicates a second with one or more errors.

15 minute

Threshold:

1—900

0 to disable

24 hour

Threshold:

1—86400

0 to disable