DCSU T1 Craft Interface
Verilink DCSU 2911 User Manual
3-19
C
Configure Thresholds: To disable any or all alarm conditions, enter a
threshold value of 0. To enable a condition, specify any non-zero
threshold value.
Refer to
for
details on the
configuration
parameters.
S
Alarm Status: Displays the counts and intervals of the LOF, LOS, RAI, AIS,
BPV, ES, and SES registers.
Options:
R) Resets Counters: Restarts the values of the LOF, LOS, RAI, AIS, BPV, ES
15 minute, ES 24 hours, SES 15 minute, and SES 24 hour counters. It
resets their values to 0.
X) Exits the Net Port Alarm Threshold Status Menu
R) Resets the
counters
X) Exits the
menu
M
Disable/Enable Alarm Monitor: Use this option to either activate or
deactivate monitoring shelf alarms.
Toggles
between
Enable and
Disable
O
Display Alarm Buffer: Displays major and minor alarms.
Minor: These alarms do not affect traffic along the network line.
Major: These alarms indicate that performance is seriously affected, for
example, a network line failure. It prevents data from being reliably
transmitted across the circuit.
This option also shows any alarms that have been cleared.
Tn
Set Default Thresholds: Use this option to load the factory default
threshold settings.
Yes or No
(Y/N)
X
Exit the Net Port Alarm Menu