Verilink DCSU 2911 (880-502647-001) Product Manual User Manual
Page 43

DCSU T1 Craft Interface
Verilink DCSU 2911 User Manual
3-21
Following is a brief description of the configure threshold
parameters:
Table 3-11
Net Port Alarm Threshold Configuration Menu Parameters
Command
Description
Options
Pn
Alarm Reporting: When alarm reporting is enabled, it will convey any
messages indicating alarms for each port. These alarms are declared to
both the Craft interface as well as the Node Manager (if used). If this option
is set to No, even if alarm reports for individual ports are requested, they
will not be reported. The LEDs will still turn amber or red in an alarm
condition. This option is best set to No while setting up or reconfiguring
your node, and then set to Yes during normal operation.
Yes or No
(Y/N)
Fn
Loss-of-Frame (LOF) Threshold/LOF Interval: Use this option to indicate an
interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
3—86400
seconds
Ln
Loss of Signal (LOS) Threshold/LOS Interval: Use this option to indicate an
interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
3—86400
seconds
Rn
Remote Alarm Indication (RAI) Threshold/RAI Interval: Use this option to
indicate an interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
1—86400
seconds
An
Alarm Indication Signal (AIS) Threshold/AIS Interval: Use this option to
indicate an interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
1—86400
seconds
Bn
Bipolar Violation (BPV) Threshold/BPV Interval: Use this option to indicate
an interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
1—86400
seconds
En
Errored Seconds (ES) 15 min. Threshold/ES 24 hr. Threshold: An ES alarm
indicates a second with one or more errors.
15 minute
Threshold:
1—900
0 to disable
24 hour
Threshold:
1—86400
0 to disable