Indicators are described on page 9.

Any of the 23 B Channels (voice channels) of the ISDN-PRI connection can process a 911

call.

Call Status

Description

OFF

No 911 call activity (idle).

Solid Yellow

911 Call Setup is in progress, no voice connection

established.

Solid Green

911 call in progress, voice connection established.


System Status

Meaning

Description

Flashing Green

Normal, OK

Power applied and processor functioning

correctly.

Flashing Yellow

System Test

Mode

Self Test Mode Switch is activated or missing

administration files.

Flashing Red

Not Functioning Self Test failure.

OFF

Not Functioning Power not applied or system not functioning.


PRI-U Status

Meaning

Description

Solid Green

Normal, OK

The PRI-U port is functioning properly.

Solid Yellow

PBX

Out of Service

The 9145 is receiving Remote Alarm Indication

(RAI), also known as a Yellow Alarm.

Flashing

Yellow

9145

Out of Service

The 9145 is transmitting Remote Alarm

Indication (RAI), also known as a Yellow Alarm.

Check system Active Alarms for details.

Flashing Green

Malfunctioning

PRI-U Bipolar Violations or Frame Slips have

occurred.

Flashing Red

Not Functioning

The 9145 is receiving an Alarm Indication

Signal (AIS), also known as a Blue Alarm.

Solid Red

Not Functioning

No ISDN-PRI digital signal is being detected,

Loss of Signal (LOS).

OFF

Not Functioning

Power not applied, system not functioning.