Teo NT1B-300TC-TSG User Manual
Nt1b-300tc-tsg, Installation instructions
The Tone Commander
NT1B-300TC-TSG converts
an ANSI standard 2B1Q
ISDN U-interface from the
telco Central Office to an
S/T interface to connect to
local customer terminal
equipment. Both
point-to-point and multipoint
ISDN terminal equipment
configurations are
supported.
The NT1B-300TC-TSG is
intended for use in
standalone applications
with TSG-6 approved S/T
interface ISDN terminals,
such as the L3
Communication Systems
STE, or the Tone
Commander 6220T-TSG,
where the NT1 is collocated
within the SCIF area.
This model complies with ANSI T1.601-1992 and T1.605-1991
interface standards, including MLT (Mechanized Loop Testing)
requirements, and is compatible with National-1 and National-2
ISDN standards. The NT1B-300TC-TSG is a modified version
of the Tone Commander NT1B-300TC, with special hardware
modifications to support TSG security requirements.
Complete metallic disconnection of the U interface on the ISDN
Line jack is provided when the NT1 is not powered, and the
design ensures that unintentional microphonic audio signals are
not detectable on external wiring.
Specifications
Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 – 56.5 VDC
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.95 W typical,
from included 901034 Desktop Power Supply
Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5
“ x 2.1” x 1.1“
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 oz.
Operating Temperature. . . . . . . . . . . . . . . . . . . . 0° – 50° C (32° – 122° F)
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . 5% to 95%, non-condensing
Standards Compliance . . . . . . . . . . . . ANSI T1.601-1992, T1.605-1991
FCC Part 15, Part 68
UL, cUL Listed
Important Safety Instructions
·
Never install telephone wiring during a lightning storm.
·
Never install telephone jacks in wet locations unless the jack
is specifically designed for wet locations.
·
Never touch uninsulated telephone wires or terminals unless
the telephone line has been disconnected at the network
interface.
·
Use caution when installing or modifying telephone wires.
·
Only power the NT1 from the included Tone Commander
Desktop Power Supply (Model 901034).
·
Do not mount the NT1B-300TC-TSG within 12
“ of a heat
source.
FCC Requirements
The Tone Commander NT1B-300TC-TSG has been tested and
found to comply with the limits for a Class B digital device, pursuant
to
Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a residential environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. However,
there is no guaranty that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
·
Where it can be done safely, re-orient the receiving television or
radio antenna.
·
To the extent possible, increase the separation between the
telephone equipment and the television, radio, or other
equipment.
·
If your telephone equipment runs on AC power, plug your product
into an AC outlet that is not on the same circuit as the one used
by your radio or television receiver.
The Tone Commander NT1B-300TC-TSG complies with
Part 68 of
the FCC Rules. The label affixed to this equipment contains, among
other information, the FCC Registration for this equipment. You
must, upon request, provide this information to your telephone
company
The following jacks must be ordered from the telephone company in
order to interconnect this product with the public communication
network: RJ49C. A plug and jack used to connect this equipmrnt to
the premises wiring and telephone network must comply with the
applicable FCC Part 68 rules and requirements adopted by the
ACTA.
If your NT1B-300TC-TSG causes harm to the telephone network,
the telephone company will notify you in advance that temporary
discontinuance of service may be required. But if advance notice
isn't practical, the telephone company will notify the customer as
soon as possible. Also, you will be advised of your right to file a
complaint with the FCC if you believe it is necessary.
Your telephone company may make changes in its facilities,
equipment, operations or procedures that could affect the proper
functioning of your equipment. If this happens, the telephone
company will provide advance notice in order for you to make
necessary modifications to maintain uninterrupted service.
Repair work on this unit must be done by the manufacturer, Teo.
Connectors
Two terminal connectors are provided for convenient terminal
installation; both are parallel connected to the S/T interface.
NT1B-300TC-TSG
Installation
Instructions
!