SVSi N2000 Series User Manual
Page 45

Page 45
N2000 Series User Manual
www.svsiav.com
Chapter 3. Encoder Options
Advanced Settings
IR Command
Holdoff
Set the delay between IR command
portions. The default setting is 25 ms.
IR commands are sent in two parts.
This setting is the time (in
milliseconds) between transmission of
part one and part two. The second part
of the command is inverted for
confirmation purposes.
IR Repeat Holdoff
Set the repeat delay between IR
commands. The default setting is 90
ms.
This is the amount of time before a
new command is sent. For example,
when pressing and holding the volume
button on a remote control, this is how
long until the command is repeated.
Maintain Aspect
Ratio
When scalers are enabled, enabling
this check box maintains the source’s
aspect ratio.
Enable SNMP
Enable to allow the device to handle
Simple Network Management Protocol
(SNMP) queries.
Table 3-2. Settings Page: Advanced Settings (Continued)
Option
Description
Notes