beautypg.com

Sundance SMT310 v.1.6 User Manual

Page 18

background image

Page 18 of 50

SMT310 User Manual V1.6

allows cable less connection between the TIM site and the buffer. There is also a 14-
way surface-mount FMS connector allowing the buffer to be connected to some
external source of data. When this connector is used, all other quick switch TIM site
connections are removed.

As well as the 12 C4x ComPort signals and signal grounds, there are 6 additional
signals. Note that these signals are NOT essential for communications:

Name

Description

I/O_OUT

Output high when port is outputting data, output low when
port is receiving data.

I/O_IN

Input which prevents bus contention if connected to I/O_OUT

/RST_OUT

Active low open collector copy of the board reset drive.

/RST_IN

Active low board reset input, pulled up to 3.3V by 100 ohms.

VCC

1 AMP +5 Volt supply, with resettable 1 Amp fuse, to power a
remote buffer, if required.

SHIELD

Overall cable shield, connected to plug shells and chassis.

The /RST_OUT is intended to allow synchronised reset of a number of boards by
driving the /RST_IN input.

The ComPort configuration register controls the way in which the quick switches
route the TIM site ComPorts to the buffer (see table 4). There is also an overall
enable bit CENb that must be set to enable the quick switches.