Lavatory system rough-in – Sloan ELC-81000 Installaton User Manual
Page 2

18”
(457 mm)
FACE
OF
WALL
15”
(381 mm)
15”
(381 mm)
30”
(762 mm)
CENTERLINE
B
(SEE CHART)
3-25/32”
(96 mm)
FINISHED
FLOOR
20-7/16”
(519 mm)
CENTERLINE
17-7/16”
(392 mm)
3”
(76 mm)
1/2” HOT/COLD
SUPPLY LINES
1-1/2” (38 mm)
DRAIN
110 VOLT, 60 Hz
15 AMP, GFCI
PROTECTED
ELECTRICAL
OUTLET (BY OTHERS)
9”
(229 mm)
8-1/2”
(216 mm)
A
(SEE CHART)
4”
(102 mm)
C
(SEE CHART)
LAVATORY SYSTEM ROUGH-IN
MODEL ELC-81000
Single Station Lavatory System
Lavatory System Weight (Packaged):
Approximately 104 Lbs/47 Kg
FACE
OF
WALL
18”
(457 mm)
15”
(381 mm)
15”
(381 mm)
30”
(762 mm)
B
(SEE CHART)
3-25/32”
(96 mm)
20-7/16”
(519 mm)
60”
(1524 mm)
15”
(381 mm)
15”
(381 mm)
30”
(762 mm)
CENTERLINE
CENTERLINE
CENTERLINE
CENTERLINE
17-7/16”
(392 mm)
3”
(76 mm)
C
(SEE CHART)
1/2” HOT/COLD
SUPPLY LINES
OPTIONAL PROTECTED
ELECTRICAL OUTLET,
DEPENDENT ON
SELECTED FAUCET
MODEL
FINISHED
FLOOR
8-1/2”
(216 mm)
A
(SEE CHART)
1-1/2”
(38 mm)
DRAIN
9”
(229 mm)
4”
(102 mm)
1-1/2”
(38 mm)
DRAIN
(OPTIONAL)
110 VOLT, 60 Hz
15 AMP, GFCI
PROTECTED
ELECTRICAL
OUTLET (BY OTHERS)
9”
(229 mm)
4”
(102 mm)
MODEL ELC-82000
Double Station Lavatory System
Lavatory System Weight (Packaged):
Approximately 171 Lbs/78 Kg
VARIABLE MOUNTING HEIGHT CHART — Single, Double & Triple Station
DIMENSION
T.A.S.
T.A.S.
A.D.A.
DESCRIPTION
AGES 4-10
AGES 11-15
STANDARD
A
ROUGH-IN
18” (457 mm)
20” (508 mm)
22” (559 mm)
B
RECOMMENDED RIM HEIGHT 29-15/16” (760 mm) 31-15/16” (811 mm) 33-15/16” (862 mm)
C
FLOOR CLEARANCE MAX
12-1/2” (318 mm)
14-1/2” (368 mm)
16-1/2” (419 mm)
D
NOMINAL FRAME HEIGHT ‡
28-17/32” (725 mm) 30-17/32” (775 mm) 32-17/32” (826 mm)
‡
Refer to Step 2.
2