beautypg.com

Valve rough-ins – Sloan 110 Dolphin Flushometer User Manual

Page 2

background image

FIN.

FLOOR

FIN.

WALL

CENTERLINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN)

4-3/4” (121 mm)

2-1/4”

(57 mm) MIN.

CENTERLINE

OF WASTE

11-1/2”

(292 mm)

FIN.

FLOOR

FIN.

WALL

CENTERLINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN)

4-3/4” (121 mm)

2-1/4”

(57 mm) MIN.

CENTERLINE

OF WASTE

24”

(610 mm)

FIN.

FLOOR

FIN.

WALL

CENTERLINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN)

4-3/4” (121 mm)

2-1/4”

(57 mm) MIN.

11-1/2”

(292 mm)

FIN.

WALL

CENTERLINE

OF FIXTURE

3/4” I.P.S.

SUPPLY

(20 mm DN)

4-3/4” (121 mm)

2-1/4”

(57 mm) MIN.

CENTERLINE

OF WASTE

11-1/2”

(292 mm)

FIN.

WALL

CENTERLINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN)

4-3/4” (121 mm)

2-1/4”

(57 mm) MIN.

24”

(610 mm)

FIN.

WALL

CENTERLINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN)

4-3/4” (121 mm)

2-1/4”

(57 mm) MIN.

CENTERLINE

OF WASTE

11-1/2”

(292 mm)

CENTERLINE

OF FIXTURE

1/2” I.P.S.

SUPPLY

(15 mm DN)

4-3/4” (121 mm)

2-1/4” (57 mm)

MIN.

9”

(229 mm)

CENTERLINE

OF FIXTURE

1/2” I.P.S.

SUPPLY

(15 mm DN)

4-3/4” (121 mm)

2-1/4”

(57 mm) MIN.

12-1/2”

(317 mm)

CENTERLINE

OF WASTE

6-1/2”

(165 mm)

MIN.

1/2”

(13 mm)

1/2”

(13 mm)

FIN.

FLOOR

FIN.

WALL

CENTERLINE

OF WASTE

FIN.

FLOOR

FIN.

FLOOR

FIN.

FLOOR

MODEL 110 — Water Saver, 3.5 gpf (13.2 Lpf)

MODEL 111-1.6 — Low Consumption, 1.6 gpf (6.0 Lpf)

MODEL 115 — Water Saver, 3.5 gpf (13.2 Lpf)

MODEL 115-1.6 — Low Consumption, 1.6 gpf (6.0 Lpf)

MODEL 120 — Water Saver, 3.5 gpf (13.2 Lpf)

MODEL 120-1.6 — Low Consumption, 1.6 gpf (6.0 Lpf)

MODEL 186-1.0 — Low Consumption, 1.0 gpf (3.8 Lpf)

Shipboard Model Type I

Class A Shock Proof — 3.5 gpf (13.2 Lpf)

Shipboard Model Type II

Class A Shock Proof — 1.0 gpf (3.8 Lpf)

Shipboard Model Type I

Class B Rigid Installation — 3.5 gpf (13.2 Lpf)

Shipboard Model Type II

Class B Rigid Installation — 1.0 gpf (3.8 Lpf)

2

Dolphin Flushometer factory settings are made at 40 psi (275

kPa). Actual flush volume will vary with pressure and flow rate.
VALVE FLUSH VOLUME ADJUSTMENT RANGE
Closet: 0.5 to 16.0 gpf (1.9 to 60.6 Lpf)
Urinal: 0.25 to 12.0 gpf (0.9 to 45.4 Lpf)

Items shown by dotted lines are NOT supplied by Sloan Valve

Company. Shock Proof Installations do NOT include fixture

connections, clamps or rubber hoses.

For Saltwater, Seawater and all Shipboard Flushometers,

Sloan Valve Company recommends furnishing Dolphin Valves

with a Ground Joint Supply Stop. Specify “-GJ” (Ground Joint)

variation. Standard Shipboard Flushometers use Ground Joint

Supply Stops.

Saltwater and other non-potable water supplies do not typically

require the use of Vacuum Breakers. To order a Flushometer

without a Vacuum Breaker, specify “-XYV” variation.

Shipboard Flushometer Valves can be supplied with a Sil-Braze

Inlet Adapter. Please specify when ordering. For Type I Water

Closet applications, use a 1” (25 mm) adapter. For Type II Urinal

applications, use a 1/2” (13 mm) adapter.

NOTES

VALVE ROUGH-INS

MODEL 110/111

MODEL 186

MODEL 115

SHIPBOARD MODEL TYPE I
CLASS A SHOCK PROOF

SHIPBOARD MODEL TYPE I
CLASS B RIGID INSTALLATION

MODEL 120

SHIPBOARD MODEL TYPE II
CLASS A SHOCK PROOF

SHIPBOARD MODEL TYPE II
CLASS B RIGID INSTALLATION

This manual is related to the following products: