The Test Sequence Details window allows you to enter details of the Test Sequence including the Test
Sequence name, the specifics of the tests to be carried out, and whether the test should Include Visual
Inspection and Include Polarity Test.
For each of the available tests, in this case Socket, Earth Bond, Insulation, Substitute Leakage, Flash,
Leakage, Touch Leakage and RCD Test, select from the list of options for Output, Limit, Test Duration
and No. of Tests. For any tests you do not wish to include in the Test Sequence, set Limit to Skip.
Test Sequence Details window
Click OK to add the Test Sequence. The Test Sequence will now appear in the
Main Window
.
Main Window - New Test Sequence
Uploading Test Sequences
To upload a Test Sequence to your tester, ensure the compatible Instrument is connected to the PC. Right-
click the Test Sequence name in the
Main Window
and select Upload Test Sequence.
Changing Test Sequences
Test Sequences can be changed at any time by double-clicking the Test Sequence name in the
Main
Window
or by right-clicking on the Test Sequence in the
Main Window
and selecting Details... This will
bring up the
Test Sequence Details window
.
Deleting Test Sequences