Remko rxd, Technical data – REMKO RXD Series User Manual
Page 26
Technical data
Series
RXD 260
RXD 350
RXD 520
RXD 680
RXD 1200
Operating mode
Ceiling cassette for combined cooling/heating
Nominal cooling output
1)
kW
2,69
3,59
5,27
6,84
12,48
Nominal heating output
2)
kW
2,96
4,24
6,31
7,72
13,23
Energy efficiency class, cooling
1)
A
A
B
B
C
Energy efficiency ratio EER
1)
3,24
3,21
3,08
3,03
2,81
Energy efficiency class, heating
2)
A
A
C
C
D
Coefficient of performance COP
2)
3,65
3,62
3,25
3,22
3,01
Operating range (room volume), approx.
m³
80
110
160
230
400
Adjustment range, room temperature
°C
+16 to +30
Working range of indoor unit
°C
+15 to +35
Refrigerant
R 410A
Operating pressure max. / per cooling circuit
kPa
4200 / 4200
Air flow rate per stage
m³/h
252/300/360
348/420/510
468/564/624
690/840/1020 978/1188/1380
Noise output per stage
3)
dB(A)
29/37/38
30/37/39
35/41/43
32/39/40
40/47/49
Voltage supply
V/Hz
230 / 1~ / 50
Protection degree
IP
X0
Nom. electrical power consumption, cooling
1)
kW
0,04
0,04
0,05
0,07
0,09
Nom. electrical power consumption, heating
2)
kW
0,04
0,04
0,05
0,07
0,09
Electr. nominal power consumption cooling
1)
A
0,32
0,35
0,42
0,55
0,75
Electr. nominal power consumption heating
2)
A
0,32
0,35
0,42
0,55
0,75
Refrigerant connection, injection pipe
Inches
(mm)
1/4 (6,35)
1/4 (6,35)
1/4 (6,35)
3/8 (9,52)
3/8 (9,52)
Refrigerant connection, suction pipe
Inches
(mm)
3/8 (9,52)
1/2 (12,70)
1/2 (12,70)
5/8 (15,90)
3/4 (19,10)
Condensation connection
mm
19
Condensation pump, delivery height
mm
1000
Dimensions of unit Height
mm
258
258
298
298
298
Width
mm
580
580
580
1110
1110
Depth
mm
580
580
580
580
580
Dimensions of cover Height
mm
28
28
28
28
28
Width
mm
650
650
650
1220
1220
Depth
mm
650
650
650
690
690
Weight
kg
26,0
26,0
27,0
59,0
59,0
Serial number
684...
687...
689...
698....
699...
Computerised part no.
1619290
1619300
1619320
1619330
1619340
1) Air inlet temperature TK 27°C / FK 19°C, outdoor temperature TK 35 °C, FK 24 °C, max. air volume, 5m pipe length in combination with RXS 261H-1200H
2) Air inlet temperature TK 20°C outdoor temperature TK 7 °C, FK 6 °C, max. air volume, 5m pipe length in combination with RXS 261H-1200H
3) Distance 1 m free air
REMKO RXD
26