beautypg.com

Installation instructions for qualified personnel – REMKO RXD Series User Manual

Page 15

background image

H

(red)

M

(yellow)

L

(green)

Cause

Required action

on

Fan at max. speed

Normal operating condition

on

Fan at medium speed

Normal operating condition

on

Fan at low speed

Normal operating condition

flashes

Heating mode: Warm-up phase

Wait approx. 1 minute

flashes

Heating mode: Cool-down phase

Wait approx. 1 minute

flashes

on

Heating mode: De-frost phase

Normal operating condition

on

flashes

flashes

Sensor on vaporiser faulty / tripped

Contact specialist dealer

flashes

Cooling mode: De-frost phase

Normal operating condition

flashes

on

Heating mode: Overheating protection has tripped

Wait approx. 1 minute

flashes

flashes

Sensor on outdoor components faulty / tripped

Contact specialist dealer

flashes

flashes

Sensor air circulation faulty / tripped

Contact specialist dealer

flashes

on

flashes

Low pressure fault (external only)

Contact specialist dealer

flashes

flashes

High pressure fault (external only)

Contact specialist dealer

flashes

flashes

on

No difference frost protection/circulation sensor

Contact specialist dealer

flashes

flashes

flashes

Condensation pump float switch faulty/tripped

Contact specialist dealer

Error and operational malfunction indicated by flashing code

Installation instructions for qualified personnel

Important points prior to
installation

Observe the manuals for
the indoor unit and outdoor
component when installing the
entire system.

Transport the unit in its original
packaging as close as possible
to the installation location to
avoid transport damage.

Check the contents of the
packaging for completeness
and check the unit for visible
transport damage. Report
any damage immediately to
your contracting party and the
shipping company.

Lift the unit at the corners
and not by the refrigerant or
condensation connections.

The refrigerant pipes (injection
and suction pipe), valves and
connections must be insulated
impervious to vapour diffusion.
If necessary, also insulate the
condensation pipe.

Select an installation location
which allows air to freely flow
through the inlet and outlet (see
section "Minimum clearances").

Do not install the unit in
the immediate vicinity of
devices with intensive thermal
radiation. Installation near
sources of thermal radiation
reduces the output of the unit.

Seal off open refrigerant pipes
with suitable caps or adhesive
strips to avoid infiltration of
moisture and never kink or
compress the refrigerant pipes.

Only use the union nuts for the
refrigerant pipes included in
the delivery, and remove them
shortly before connecting the
refrigerant pipes.

Establish all electrical
connections in accordance with
the relevant DIN- and VDE
standards.

See electrical connection
diagram Always properly
insert electrical cables into the
electrical terminals. Otherwise
a fire could result.

15