Installation instructions for qualified personnel – REMKO RXD Series User Manual
Page 15
H
(red)
M
(yellow)
L
(green)
Cause
Required action
on
Fan at max. speed
Normal operating condition
on
Fan at medium speed
Normal operating condition
on
Fan at low speed
Normal operating condition
flashes
Heating mode: Warm-up phase
Wait approx. 1 minute
flashes
Heating mode: Cool-down phase
Wait approx. 1 minute
flashes
on
Heating mode: De-frost phase
Normal operating condition
on
flashes
flashes
Sensor on vaporiser faulty / tripped
Contact specialist dealer
flashes
Cooling mode: De-frost phase
Normal operating condition
flashes
on
Heating mode: Overheating protection has tripped
Wait approx. 1 minute
flashes
flashes
Sensor on outdoor components faulty / tripped
Contact specialist dealer
flashes
flashes
Sensor air circulation faulty / tripped
Contact specialist dealer
flashes
on
flashes
Low pressure fault (external only)
Contact specialist dealer
flashes
flashes
High pressure fault (external only)
Contact specialist dealer
flashes
flashes
on
No difference frost protection/circulation sensor
Contact specialist dealer
flashes
flashes
flashes
Condensation pump float switch faulty/tripped
Contact specialist dealer
Error and operational malfunction indicated by flashing code
Installation instructions for qualified personnel
Important points prior to
installation
■
Observe the manuals for
the indoor unit and outdoor
component when installing the
entire system.
■
Transport the unit in its original
packaging as close as possible
to the installation location to
avoid transport damage.
■
Check the contents of the
packaging for completeness
and check the unit for visible
transport damage. Report
any damage immediately to
your contracting party and the
shipping company.
■
Lift the unit at the corners
and not by the refrigerant or
condensation connections.
■
The refrigerant pipes (injection
and suction pipe), valves and
connections must be insulated
impervious to vapour diffusion.
If necessary, also insulate the
condensation pipe.
■
Select an installation location
which allows air to freely flow
through the inlet and outlet (see
section "Minimum clearances").
■
Do not install the unit in
the immediate vicinity of
devices with intensive thermal
radiation. Installation near
sources of thermal radiation
reduces the output of the unit.
■
Seal off open refrigerant pipes
with suitable caps or adhesive
strips to avoid infiltration of
moisture and never kink or
compress the refrigerant pipes.
■
Only use the union nuts for the
refrigerant pipes included in
the delivery, and remove them
shortly before connecting the
refrigerant pipes.
■
Establish all electrical
connections in accordance with
the relevant DIN- and VDE
standards.
■
See electrical connection
diagram Always properly
insert electrical cables into the
electrical terminals. Otherwise
a fire could result.
15