Remko rxd – REMKO RXD Series User Manual

Page 18

background image

Connections to adjacent room
and fresh air intake

The indoor unit has been designed
to allow the cooling of a second
room as well as the intake of fresh
air.

It is only permitted to connect
one fresh air intake and one
adjacent room!

CAUTION

Installation instructions

Proceed as follows to make the
connections to a second room and
the fresh air intake:

1. Please note that the vaporiser

fins are located directly behind
the cover being removed. These
should not be damaged under
any circumstances (Fig. 8).

2. Carefully remove the insulation

behind the opening (Fig 9).

3. Break through the appropriate

opening (Fig. 10).

4. Keep the ventilation pipes as

short as possible and lay them
in such as way as to minimise
the amount of bends.

5. The collars, screws, flexible /

folded spiral seam pipes and
insulation materials should be
provided by the customer.
The above items can be
obtained from specialist
suppliers (Fig. 11).

8 Remove the cut-out

9 Carefully remove the insulation

10 Break through the opening

11 Attaching the pipe collar

Connections to adjacent room and fresh air intake

Fresh air intake

Connection to

adjacent room

Connection to

adjacent room

Fresh air intake

Connection to

adjacent room

Connection to

adjacent room

Fresh air intake

REMKO RXD

18