Page 18
Connections to adjacent room
and fresh air intake
The indoor unit has been designed
to allow the cooling of a second
room as well as the intake of fresh
air.
It is only permitted to connect
one fresh air intake and one
adjacent room!
CAUTION
Installation instructions
Proceed as follows to make the
connections to a second room and
the fresh air intake:
1. Please note that the vaporiser
fins are located directly behind
the cover being removed. These
should not be damaged under
any circumstances (Fig. 8).
2. Carefully remove the insulation
behind the opening (Fig 9).
3. Break through the appropriate
opening (Fig. 10).
4. Keep the ventilation pipes as
short as possible and lay them
in such as way as to minimise
the amount of bends.
5. The collars, screws, flexible /
folded spiral seam pipes and
insulation materials should be
provided by the customer.
The above items can be
obtained from specialist
suppliers (Fig. 11).
8 Remove the cut-out
9 Carefully remove the insulation
10 Break through the opening
11 Attaching the pipe collar
Connections to adjacent room and fresh air intake
Fresh air intake
Connection to
adjacent room
Connection to
adjacent room
Fresh air intake
Connection to
adjacent room
Connection to
adjacent room
Fresh air intake
REMKO RXD